when the lights are on, all three wires are at the same potential -and- my indicator screwdriver says they're all live. when the lights are off there's 220Vac between BLU and BRN, and 10Vac (what) between BLU and G/Y. I don't even know.
-
-
"oh look a piece of tape i bet that's just junk let me rem..." so the person who installed the lamp managed to cut the insulation of wire that DID NOT HAVE OUTER PVC SHEATH. HOW. HOW ARE YOU THIS BAD AT ITpic.twitter.com/W6ZN5LQ6R3
এই থ্রেডটি দেখান -
if this house wasn't slated for demolition in several years (no one in the government can coherently say when, only that it is. they used to say this year but then they did cosmetic repair instead, because that makes sense) I would literally just replace all wiring and appliances
এই থ্রেডটি দেখান -
honestly tempted to do it anyway but that's like 30-50m of new wiring to put in cable channels and it's both expensive (copper aint cheap) and labor intensive so I'll reuse the old wiring in walls on the assumption that LED lamps are just not enough current, and redo junctions
এই থ্রেডটি দেখান -
correction: that breaker switched off all sockets except precisely two completely arbitrary oneshttps://twitter.com/whitequark/status/1013856560970457088 …
এই থ্রেডটি দেখান -
so basically there's both lighting and sockets in apparently random arrangement on two 16A circuits and there's a third one that powers nothing but a washing machine and bathroom mirror light. because that makes sense.
এই থ্রেডটি দেখান -
hellooo there, flying spaghetti monster inside the ceiling lamp. i don't even want to think what hides in the other lampspic.twitter.com/xhf2wJAwez
এই থ্রেডটি দেখান -
I -very- gently pulled at one of the wires going into the screw terminal and it literally just fell out. THIS IS FINE
এই থ্রেডটি দেখান -
replaced it all with fresh, not horribly oxidized copper wiring (the one that was screwed in was pretty much black) that's crimp terminated on both ends and then goes into a Wago spring clamp not the prettiest job but it won't catch fire for surepic.twitter.com/hj9WhEVoX2
এই থ্রেডটি দেখান -
the mechanical skills of the person who installed the lamp are on par with electrical. the mounting holes don't lie on the line drawn under the lamp. they aren't parallel to the walls (or anything else anywhere) eitherpic.twitter.com/3vmdA4AVXX
এই থ্রেডটি দেখান -
the old insulation (unidentifiable crumbling polymer under unidentifiable crumbling cloth braiding) was in an extremely bad state so I gave it a makeover with some (correctly colored) heatshrinkpic.twitter.com/eUVS5F1O6v
এই থ্রেডটি দেখান -
Wago CAGE-CLAMP 222 series is spec'd for aluminium, see Wago website https://www.wago.com/global/installation-terminal-blocks-and-connectors/compact-splicing-connector/p/222-413 …https://twitter.com/11rcombs/status/1013886151336382465 …
এই থ্রেডটি দেখান -
mystery of the hot G/Y conductor: solved I will find the trash who has worked on wiring in this house, and I will skewer him on a hot protective earth wirepic.twitter.com/o6yLNHDos3
এই থ্রেডটি দেখান -
to recap: the brown wire here is -neutral-, and blue and green-yellow are switched, and normally hot because they're energized through the lamp. the G/Y wire in the junction box misses a chunk of insulation in the middle, too, just for kicks
এই থ্রেডটি দেখান -
I don't think I can tear up walls here so I did the next best thing: switched G/Y to be neutral and indicated the real purpose of wiring with a heatshrink sleevepic.twitter.com/nsTr0RYI8u
এই থ্রেডটি দেখান -
when they say "you can twist copper" they don't mean twist LIKE THISpic.twitter.com/B9WDoV0yNn
এই থ্রেডটি দেখান -
in case you thought this thread can't get any worse, we have a code violation bingo! behold: exactly 5cm of copper wire extremely badly twisted together with decaying aluminium wire. there was enough length to not do this extension, he could have just put the junction box higherpic.twitter.com/Daf8q70v2H
এই থ্রেডটি দেখান -
also the decaying aluminium wire was load-bearing: the junction box was "fixed" to the wall with a single screw (naturally, not going through the hole specifically meant for a screw) but mostly held in place by wiring
এই থ্রেডটি দেখান -
by the way, directly above the load-bearing junction box with the aluminium-copper twist there was a polystyrene foam ceiling tile, glued to it badly enough that it fell off and is now solely supported by wiring that rests on threads of screws mounted into the wall
এই থ্রেডটি দেখান -
I mean, saying that the aluminium-copper twist was "in" the junction box is doing it a favor. it was "near" the junction box. "in the general area" is perhaps a good way to describe it.
এই থ্রেডটি দেখান -
more photos of the mystery junction box. looks like there's another generation of wiring going somewhere... down. I do not know if it is hot, and I dare not check. I do not know where it goes eitherpic.twitter.com/UQ7G9w81BD
এই থ্রেডটি দেখান -
as you can see, this junction box has three exposed wires. left to right. 1: neutral. 2: living room ceiling light 1. 3: living room ceiling light 2. 4: bedroom ceiling light and -all bedroom sockets-. yes. the ENTIRE BEDROOM, including SOCKETS is designed for SWITCHED NEUTRAL.
এই থ্রেডটি দেখান -
*wakes up* i'm this close to giving up. not because i can't fix this--even more depressingly, the fix is near trivial far as i can see--but because of a severe, life-threatening shortage of even. specifically...
এই থ্রেডটি দেখান -
based on the appearance of the junction, either the original builders set up this switched neutral thing, or someone else after them has deliberately (you can't do this accidentally) swapped phase and neutral in the main distribution box and i don't know which option is worse
এই থ্রেডটি দেখান -
i will never make fun of anything related to computers again because no thing in the entire history of computing was done as badly and as hazardously as wiring in this house yes, i know about therac 25. this is more like a fractal therac 25.
এই থ্রেডটি দেখান -
I opened the only circuit in the apartmet with apparently intact grounding and not only the copper wiring is improperly terminated (it ah... fell out when I opened the socket), but also the protective earth is broken in at least two independent points
এই থ্রেডটি দেখান -
no, ${anonymous_electrician_who_i_know_for_sure_has_a_state_license}, you do not crimp wire ferrules with -pliers-. not now, not ever.
এই থ্রেডটি দেখান -
well this would certainly explain why a correctly wired socket in the kitchen had phase on the proper contact in spite of the cable going to the distribution box being connected backwards (phase and neutral swapped) same licensed electrician btwpic.twitter.com/JTaOvNLSxD
এই থ্রেডটি দেখান -
please note the single screw that pretends to keep it in place and, yet again, load-bearing wiring
এই থ্রেডটি দেখান -
to be clear, yes, the multistrand copper cable from the distribution box goes through the bathroom socket, is poorly squished into a socket that is designed for singlestrand copper exclusively, and, after going through socket contacts, swaps phase and neutral and continues on
এই থ্রেডটি দেখান -
well, and -this- would certainly explain why there's an earth fault. the ... creature who did this part of wiring removed the insulation with a knife on all of phase, zero and ground, phase shorted to ground and burned it off. no GFCI, nothing to prevent thispic.twitter.com/wBjMoGG1LH
এই থ্রেডটি দেখান - 4টি আরও উত্তর